Nadelhalter nach Baumgartner L 14 cm (1 Stck)

Baumgartner Needle Holder L 14 cm (1 pc)

MD20210
€113,80
Sale price  €113,80 Regular price 
Net price per sales unit plus statutory VAT.
Shipping calculated at checkout.
Needle holder according to Baumgartner,
medium length 14 cm,
reusable,
rough gripping surface, fine edges

Scope of delivery: 1 piece, non-sterile.

Care tips for surgical instruments made of stainless steel class 1A or 1B
(suitable for sterilization with hot air, steam or gas)

Stainless steel remains rust-free only if it is treated correctly:

Before first use, the instrument should be thoroughly cleaned with a soft brush and then freed from all detergent residues under distilled water to ensure that all manufacturing residues are rinsed off.

After use, instruments must be soaked immediately so that tissue particles, blood, protein and corrosive medicines do not dry onto the instrument. Instrument joints must be wide open, and detachable parts must be disassembled.

During cleaning, all joints, teeth, grooves, cutting edges, through-holes, ratchets, jaws and all other concave depressions must be checked for any residues and cleaned, as these could stick so firmly during sterilization that the instrument's mobility and overall function would be impaired.

It is then important to thoroughly rinse the instruments with distilled or demineralized water, as tap water contains corrosive substances (e.g. chlorides, nitrides, nitrates, sulfides, sulfates and rust particles) that would attack the stainless steel during the sterilization process. The possible consequences of incorrect treatment could be:
• tarnished, discolored, stained or rusted instruments
• Chloride pitting corrosion or stress corrosion cracking

The cleaned instruments must be dried by hand and then oiled with pure paraffin oil (DAB8). The instruments must then be stored on a soft surface in non-overfilled sterilization baskets (place heavy parts at the bottom, light parts at the top).
The sterilization process can now be initiated.
The instruments may only be stored completely clean and dry, with open locks, in suitable containers, instrument cabinets or cases.
The instruments must not be used for purposes other than those intended, as they are only designed and resilient for their respective function. Appropriate tools should be available for any mechanical work. The warranty expires if the instruments are misused or treated incorrectly.

Reprocessing instructions can be found in the operating instructions below.